8.4 Serial Line Protocol
The Gemini system supports a subset of the Meade LX200 Command Set, with some
extensions added. From Level 2 up, nearly all Gemini parameters and settings can be
downloaded or uploaded using the native command set described at the end of the page.
Syntax: values in <> are (to be) replaced by actual values. Curled brackets {} show
alternative characters.
Upon completion, ASCII characters or strings are returned, if indicated.
Command
Returns
Remarks
Usable for testing the serial link and
determining the type of mount
(German equatorial).
During Startup, with a "b#" being
returned, the PC can select the startup
G# after completed
mode by sending a
startup or
0x06 (ACK char)
b# while waiting for
bC# for selecting the Cold
the selection of the
Start,
Startup Mode.
bW# for selecting the Warm
Start and
bR# for selecting the Warm
Restart.
Synchronize
The string "No object!#" is returned
if the mount is not aligned or no
object was selected, otherwise the
name of the selected object used is
No object!# or
:Cm#
returned.
This command does an "Additional
Alignment", (re)calculating the
pointing model parameters and
synchronizing to the position given.
The string "No object!#" is returned
if the mount is not aligned or no
object was selected, otherwise the
No object!# or
:CM#
name of the selected object used is
returned.
The position (RA and DEC) is
synchronized to the position of the
Gemini Users Manual